Availability: | |
---|---|
H013~H300
Nuochen
Introduction
Hot Sale With CE Heat Exchangers Stainless Steel Brazed Plate Heat Exchangers for Beverages and Milk
Applications:
Outdoor wood furnaces/boilers
Radiant Floor Heating
Plumbing Systems
Snowmelt Systems
Swimming Pools
HVAC and refrigeration systems
Solar heating
Other liquid to liquid heat transfer applications
refrigerant Brazed Plate Heat Exchanger
Benefits
• Small and Compact
• Easy to install
• Self-cleaning
• All are pressure and leak tested
• Gasket free
•Wort Chiller titanium Brazed Plate Heat Exchanger
Design
Brazing material seals and holds the plates together at the contact points ensuring optimal heat transfer efficiency and pressure resistance.
Using advanced design technologies and extensive verification guarantees the highest performance and longest possible service life.
Different pressure ratings are available for different needs.
The unit can be supplied with a refrigerant distribution system for optimal evaporator performance.
liquid 20kw Brazed Plate Heat Exchanger
Based on standard components and a modular concept, each unit is custom-built to meet the specific requirements of each individual installation.
Model | High H | Width B | Thickness C | Longitudinal Hole Distance H0 | Horizontal Hole Distance B0 | Weight kg | Unilateral Stagnation Valume(L) | Heat Exchanger Area m2 |
H013 | 192 | 78 | 2.3*N+9 | 152 | 40 | 0.04*N+0.4 | (N-2)*0.008 | (N-2)*0.013 |
H014 | 208 | 76 | 2.3*N+9 | 168 | 42 | 0.05*N+0.5 | (N-2)*0.01 | (N-2)*0.014 |
H015 | 200 | 90 | 2.1*N+9 | 160 | 46 | 0.05*N+0.4 | (N-2)*0.011 | (N-2)*0.015 |
H016 | 200 | 90 | 3.1*N+9 | 160 | 46 | 0.05*N+0.5 | (N-2)*0.014 | (N-2)*0.016 |
H020 | 310 | 76 | 2.3*N+9 | 282 | 42 | 0.058*N+1 | (N-2)*0.018 | (N-2)*0.02 |
H026 | 310 | 111 | 2.4*N+9 | 250 | 50 | 0.11*N+1 | (N-2)*0.025 | (N-2)*0.026 |
H030 | 325 | 95 | 1.55*N+9 | 269 | 39 | 0.09*N+1 | (N-2)*0.03 | (N-2)*0.03 |
H050 | 525 | 111 | 2.4*N+9 | 466 | 50 | 0.2*N+2.4 | (N-2)*0.05 | (N-2)*0.05 |
H060 | 527 | 120 | 2.3*N+9 | 479 | 72 | 0.19*N+2.4 | (N-2)*0.11 | (N-2)*0.06 |
H095A | 616 | 191 | 2.45*N+11 | 519 | 92 | 0.36*N+7.8 | (N-2)*0.1 | (N-2)*0.095 |
H095B | 616 | 191 | 2.8*N+11 | 519 | 92 | 0.44*N+7.8 | (N-2)*0.12 | (N-2)*0.095 |
H095C | 616 | 191 | 2.8*N+11 | 519 | 92 | 0.44*N+7.8 | (N-2)*0.12 | (N-2)*0.095 |
H100 | 490 | 250 | 2.8*N+11 | 391 | 157 | 0.35*N+6.5 | (N-2)*0.08 | (N-2)*0.1 |
H110 | 528 | 246 | 2.4*N+12 | 456 | 174 | 0.52*N+6.5 | (N-2)*0.19 | (N-2)*0.11 |
H190 | 698 | 307 | 2.65*N+13 | 567 | 179 | 0.51*N+10 | (N-2)*0.21 | (N-2)*0.19 |
H210 | 739 | 322 | 2.55*N+13 | 599 | 211 | 0.82*N+13 | (N-2)*0.2 | (N-2)*0.21 |
H220 | 734 | 319 | 2.65*N+13 | 622 | 205 | 0.7*N+13 | (N-2)*0.22 | (N-2)*0.22 |
H300 | 1006 | 366 | 2.8*N+16 | 872 | 228 | 1.26*N+57 | (N-2)*0.35 | (N-2)*0.3 |
Introduction
Hot Sale With CE Heat Exchangers Stainless Steel Brazed Plate Heat Exchangers for Beverages and Milk
Applications:
Outdoor wood furnaces/boilers
Radiant Floor Heating
Plumbing Systems
Snowmelt Systems
Swimming Pools
HVAC and refrigeration systems
Solar heating
Other liquid to liquid heat transfer applications
refrigerant Brazed Plate Heat Exchanger
Benefits
• Small and Compact
• Easy to install
• Self-cleaning
• All are pressure and leak tested
• Gasket free
•Wort Chiller titanium Brazed Plate Heat Exchanger
Design
Brazing material seals and holds the plates together at the contact points ensuring optimal heat transfer efficiency and pressure resistance.
Using advanced design technologies and extensive verification guarantees the highest performance and longest possible service life.
Different pressure ratings are available for different needs.
The unit can be supplied with a refrigerant distribution system for optimal evaporator performance.
liquid 20kw Brazed Plate Heat Exchanger
Based on standard components and a modular concept, each unit is custom-built to meet the specific requirements of each individual installation.
Model | High H | Width B | Thickness C | Longitudinal Hole Distance H0 | Horizontal Hole Distance B0 | Weight kg | Unilateral Stagnation Valume(L) | Heat Exchanger Area m2 |
H013 | 192 | 78 | 2.3*N+9 | 152 | 40 | 0.04*N+0.4 | (N-2)*0.008 | (N-2)*0.013 |
H014 | 208 | 76 | 2.3*N+9 | 168 | 42 | 0.05*N+0.5 | (N-2)*0.01 | (N-2)*0.014 |
H015 | 200 | 90 | 2.1*N+9 | 160 | 46 | 0.05*N+0.4 | (N-2)*0.011 | (N-2)*0.015 |
H016 | 200 | 90 | 3.1*N+9 | 160 | 46 | 0.05*N+0.5 | (N-2)*0.014 | (N-2)*0.016 |
H020 | 310 | 76 | 2.3*N+9 | 282 | 42 | 0.058*N+1 | (N-2)*0.018 | (N-2)*0.02 |
H026 | 310 | 111 | 2.4*N+9 | 250 | 50 | 0.11*N+1 | (N-2)*0.025 | (N-2)*0.026 |
H030 | 325 | 95 | 1.55*N+9 | 269 | 39 | 0.09*N+1 | (N-2)*0.03 | (N-2)*0.03 |
H050 | 525 | 111 | 2.4*N+9 | 466 | 50 | 0.2*N+2.4 | (N-2)*0.05 | (N-2)*0.05 |
H060 | 527 | 120 | 2.3*N+9 | 479 | 72 | 0.19*N+2.4 | (N-2)*0.11 | (N-2)*0.06 |
H095A | 616 | 191 | 2.45*N+11 | 519 | 92 | 0.36*N+7.8 | (N-2)*0.1 | (N-2)*0.095 |
H095B | 616 | 191 | 2.8*N+11 | 519 | 92 | 0.44*N+7.8 | (N-2)*0.12 | (N-2)*0.095 |
H095C | 616 | 191 | 2.8*N+11 | 519 | 92 | 0.44*N+7.8 | (N-2)*0.12 | (N-2)*0.095 |
H100 | 490 | 250 | 2.8*N+11 | 391 | 157 | 0.35*N+6.5 | (N-2)*0.08 | (N-2)*0.1 |
H110 | 528 | 246 | 2.4*N+12 | 456 | 174 | 0.52*N+6.5 | (N-2)*0.19 | (N-2)*0.11 |
H190 | 698 | 307 | 2.65*N+13 | 567 | 179 | 0.51*N+10 | (N-2)*0.21 | (N-2)*0.19 |
H210 | 739 | 322 | 2.55*N+13 | 599 | 211 | 0.82*N+13 | (N-2)*0.2 | (N-2)*0.21 |
H220 | 734 | 319 | 2.65*N+13 | 622 | 205 | 0.7*N+13 | (N-2)*0.22 | (N-2)*0.22 |
H300 | 1006 | 366 | 2.8*N+16 | 872 | 228 | 1.26*N+57 | (N-2)*0.35 | (N-2)*0.3 |